| Hasco
Component's electromechanical relays range from less than
an amp to 80 amps. Hasco's relays are UL and CSA with some
TUV ratings. All relays have DC coils and many have an
AC coil. They come sealed for wave soldering and washing
thereby allowing the relays to be put on any assemble line.
There are surface mount low current relays available as
well.
HAT901CSDC24-L LATCHING RELAY
| GENERAL SPECIFICATIONS |
| Contact Material: |
silver cadmium oxide with copper base |
| Max. continuous rated voltage: |
110% of nominal voltage. |
| Contact Resistance: |
50 mOhms max. (Initial value) |
| Operating Temp: |
Class B: -200C to 85o C |
| |
Class F: -200C to 1050C |
| Insulation Resist: |
DC 500V 10 mOhms min |
| Dielectric Strength: |
AC 2000V between contact and coil, frame and
contact, coil and frame one minute. AC 1500V between contact one minute |
| Operating Time: |
approx. 15 ms |
| Release Time: |
approx 10 ms |
| Electrical Life: |
10 x 104 operating min. for 30A resistive Load (N.O.) |
| |
5 x 104 operating min. for 40A Resistive Load (N.O.) |
| Mechanical Life: |
10 x 106 operation min. |
|
PATENT PENDING |
| DC COIL RATINGS |
|
Nominal
Voltage
(VDC) |
Set/Reset
Voltage
(VDC) |
Resistance
+/- 10% @250C
(Ohms |
|
5 |
4 |
27 |
|
6 |
4.8 |
40 |
|
9 |
7.2 |
97 |
|
12 |
9.6 |
155 |
|
24 |
19.2 |
660 |
|
48 |
38.4 |
2560 |
| MAXIMUM LOAD SPECIFICATIONS |
| Voltage |
Load Type |
SPNC |
SPNO |
| AC |
Resistive |
30A 277VAC |
40A 277VAC |
| Motor |
1HP 120VAC
2HP 277VAC |
1HP 120 VAC
2HP 277VAC |
| General Purpose |
30A 277VAC |
40A 277VAC |
| Ballast |
10A 120VAC
10A 277VAC |
30A 120VAC
20A 277VAC |
| Tungsten |
2A 120VAC |
10A 120VAC |
| DC |
Resistive |
30A 28VDC |
30A 28VDC |
Shock Operational - 10g for 11ms w/no contact opening
Shock Destructive - 110g
ORDERING INFORMATION

|
WIRING DIAGRAMS
NOTE: RELAYS ARE SHIPPED IN THE “RESET STATE”. However, shock may cause this state to change. Therefore,
it is necessary to confirm the relay’s state BEFORE IT’S USE.
|